RT system with a QCA147 cabinet

Use this procedure to configure and connect the NT8D22 system monitor in
an AEM column that is connected to a Meridian SL-1 RT equipped with a
QCA147 cabinet. Refer to Figure 16 during this procedure.
Note: If you are not making alarm connections to the MDF, skip steps
3 through 6 and directly install connector P1 of the NT8D46AY cable
into connector J3 of the system monitor.
Procedure 6xxx
RT system with QCA147 cabinet connections
1
Loosen the two retaining screws on the system monitor in the pedestal
of the AEM column and remove it from the PDU.
2
Configure the system monitor as the master as shown in Table 7. (See
Circuit card installation and testing (553-3001-211) for a detailed
description of the option switch settings.)
Table 7xxx
NT8D22 switch settings (set as master) for operation with RT
Switch
1
SW1
on
SW2
on
SW3
on
* Set to off for ac power. Set to on for dc power.
3
Reinstall the system monitor in the PDU.
4
Install connector P1 of the NT8D46AY cable into connector J1 of the
NT8D46BF cable.
5
Install connector P1 of the NT8D46BF cable into connector J3 of the
system monitor.
6
Install connector J2 of the NT8D46BF cable into connector P1 of the
NT8D46BH cable.
7
Connect the other end of the NT8D46BH cable at the alarm termination
area on the MDF.
8
Power down the QCA147 cabinet.