16 Installing a stand-alone AEM
553-3201-200 Standard 1.0 April 1993
3
Remove the backplane cover on the I/O assembly in the AEM above
the pedestal, refer to Figure 10.
4
Disconnect the power plug (J1) and system monitor ribbon cable to the
AEM.
Note: To disconnect the power plug, press a latch trip on the front
and rear of the plug. You may need to use a screwdriver blade
against the latch trip on the front of the plug.
5
Loosen the retaining screws that secure the PDU.
6
If required, install a junction box near the pedestal of the AEM column.
Insert the conduit from the junction box into one of the conduit access
holes in the pedestal.
Connect the wires from the junction box to the matching connections on
TB1 in the pedestal:
a.
Connect the red wires, BAT0 through BAT3.
b.
Connect the black wires, RTN0 through RTN3.
c.
Connect the green wire, FGRD.
d.
Connect the remaining wire (which is usually orange), LRTN.
Note: If a junction box is used, the connections described in steps
4 through 7 apply to TB1 in the junction box rather than the
pedestal.
Figure 10xxx