46 Adding an AEM to a column

Adding an AEM to the base of a column

553-3201-200 Standard 1.0 April 1993
Procedure 10xxx
Adding an AEM to the base of a column
1
Remove the rear grill on the pedestal and set all circuit breakers to OFF
(down).
2
Remove the module above the pedestal:
a.
Remove all the covers on the rear of the module.
b.
Disconnect the power connector to the pedestal (see Figure 21).
Note: You must press a latch trip on the front and rear of the plug.
You may need to use a screwdriver blade against the latch trip on
the front of the plug.
c.
Disconnect the system monitor connector to the pedestal (see
Figure 21).
d.
Use a 9/16-inch socket wrench to remove the five mounting bolts
that secure the module (see Figure 22) and lift it off the column.
3
Position and secure modules:
a.
Locate the positioning guides on the pedestal (see Figure 23).
Make sure the AEM is facing the same direction as the column.
b.
Place the AEM on the pedestal and adjust it until it is seated
securely on the positioning guides.
c.
Secure the mounting bolts on the AEM.
d.
Place the removed module on top of the AEM and secure it with
the mounting bolts.
4
Connect the power and system monitor cables:
a.
Remove all the covers on the rear of the AEM.
b.
Connect the power connectors in the AEM to the pedestal and to
the module above (see Figure 21).
c.
Connect the system monitor cable from the pedestal to connector
J1 on the AEM.
d.
Connect the system monitor cable from connector J2 in the AEM to
J1 in the module above.
5
See the Application Module installation and upgrade guide
(553-3201-210) for instructions on installing the Application Module
and powering up the column.