en | Flying the system
Notice!
i
Use of a separate cable pick to support the weight of cabling is recommended, especially on
very tall arrays.
Cable weight can change the aiming angle of an array.
Refer to
9.2.2

X12TC-GRID with pull-back to venue

Using an X12TC-GRID combined with the X12PU-BGK an array can be pulled back to the
venue.
Notice!
i
Only the double pin method is allowed when pull back to the venue is planned. Do not use
single pin compression method in this instance.
To pull-back to the venue, do the following:
1.
2.
3.
4.
2019-07 | 04 | F.01U.310.953
Setting rear link angles, page 15
Stacking X1, X2, and X12-125F elements onto a dolly, page 21
Attach the X12PU-BGK bottom section with spreader bar to the bottom element.
Attach a 5/8-inch shackle (A) to the pick point on the spreader bar.
Ensure the shackle is rated for overhead lifting.
Attach the pull-back hoist chain hook (B) to the shackle.
Verify all hooks, pins, shackles, and other associated rigging components are properly
positioned and secure before lifting the array.
B
A