5-18. Tension Arm Unit
Replacement
(Removal)
1.
Remove the Cut Washer (A) and hang off the
Tension Regulator Spring, and then remove the
Tension Arm Unit as shown in Figure 5-18-1.
(Installation)
1.
Install the new Tension Arm Unit following the
removal steps in reveres order.
2.
After installation, Tension Arm Adjustment should
be performed the following steps.
Figure 5-18-1
3-3. Tension Sensor Voltage
(Tension Offset Adjustment)
3-4. Tension Sensor Voltage
(Neutral & Playback position Adjustment)
3-5. Rev Voltage Confirmation
3-6. Tension Regulator Spring
3-7. Rev Tension Confirmation
MECH-50
START
Adjustment (1)
Adjustment (2)
OK
Adjustment
OK
END
Figure 5-18-2
NG
NG