3. RF/EQ (F8)
<Automatic Adjustment Procedure>
(Software)
This software is for Automatic RF Adjustment of DVCPRO50M Studio VTR, AJ-SD930 and AJ-SD955A.
< Function >
1) RF Adjustment (DVCPRO50M/ DVCPRO25M: Rec. and Play, DV: Play)
2) Checking of Error Rate
3) Download and Upload of EVR Data
4) Saving/ Loading the data of Error Rate and EVR
5) Printing the data of Error Rate and EVR
(Before Installation)
* PC Condition
OS
: Windows95/ 98/ 98SE/ ME/ 2000 or Over
Display : Over 256 color (if lower than 256 color, the color may have the distortion)
* How to get this software
Download "Automatic RF Adjustment Software (VFK1806)" from Jig software page on BSD Web site.
* Installation Method
1) Extract the downloaded software.
2) Click "setup.exe".
3) Follow the indication.
* Un-installation Method
Open "Control Panel" on Windows and use "Add/Remove Programs" to un-install this software.
(Explanation of Each Windows)
a) Main Window
Progress Bar
Menu Bar
Progress Indication
Box
ELE-5
Message Box
Error Rate
Indication Bar
Selection Box for Adj. /
Measurement Mode.