Servo ON
Programmable controller
Station number 1
Turns on X0 (Servo ON command).
Station number 2
Turns on X10 (Servo ON command).
Programmable controller
operation
Station number 1
PowerStatus[1] (Ready to operate
status) and PowerBusy[1] (Ready
to operate (executing)) turn on.
Station number 2
PowerStatus[2] (Ready to operate
status) and PowerBusy[2] (Ready
to operate (executing)) turn on.
Executing the OPR
Programmable controller
Station number 1
Turns on X1 (OPR execution).
Station number 2
Turns on X11 (OPR execution).
Programmable controller
operation
Station number 1
HomeDone[1]
(OPR completed) turns on.
Station number 2
HomeDone[2]
(OPR completed) turns on.
*1 For how to check the servo amplifier state with MR Configurator2, refer to the following.
Page 53 How to check the servo amplifier state
5 CREATING PROGRAMS
51
5.8 Operation Check
Servo amplifiers operation
Station number 1
The SON lights in green.
Station number 2
The SON lights in green.
Servo amplifiers
operation
"Current position"
becomes 0.
<Check with the LEDs.>
FX5S
CPU module
<Check with MR Configurator2.>
Servo amplifiers
The SON is lit in
green.
*1