2.4

Parameter Settings

1.
Select [Parameter]  [Parameter Setting].
2.
Set each item from [List display]. Set the same value for both axis 1 and axis 2.
List display
Basic
I/O
Positioning control
Network
 When "Basic" is selected
No.
PA01
PA04
PA06
PA07
PD01
PD13
PT45
PN13
PN22
Name
Operation mode
Function selection A-1
Electronic gear - Numerator
Electronic gear -Denominator
Input signal automatic ON selection 1
Function selection D-2
Homing method
Network protocol setting
Function selection N-5
2 SERVO AMPLIFIER SETTING
Setting value
00003000h
00002100h
500
1
00000C00h
00000100h
-3
00000004h
00000000h
2.4 Parameter Settings
2
16