Mitsubishi Electric MELSEC iQ-F Series Quick Connection Manual page 29

Electric programmable controller for cc-link ie field network basic
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Data flow between the master station and remote stations using link devices
This manual describes data communications using cyclic transmission, for which the link devices of the servo amplifiers are
used. Each link device is assigned as shown below. For how to set global labels, refer to the following.
Page 29 Adding Structures and Global Labels
■MR-JET-G (Station number 1)
Assignment target device on the programmable controller side
B0 to B3F
B80 to BBF
W0 to W1F
W40 to W5F
■MR-JET-G (Station number 2)
Assignment target device on the programmable controller side
B40 to B7F
BC0 to BFF
W20 to W3F
W60 to W7F
Global label
(G_stlinkIEF)
bnRX[H0] to bnRX[H3F]
bnRX[H40] to bnRX[H7F]
bnRY[H0] to bnRY[H3F]
bnRY[H40] to bnRY[H7F]
unRWr[H0] to unRWr[H1F]
unRWr[H20] to unRWr[H3F]
unRWw[H0] to unRWw[H1F]
unRWw[H20] to unRWw[H3F]
Precautions
The above areas are used as the link devices for network. Do not use these areas for the other purposes.
Labels for starting communications
Among the link devices, some are assigned to labels for starting cyclic communications, as shown below.
Label name (Station number 1)
G_stlinkIEF.bnRX[H3F]
G_stlinkIEF.bnRY[H3F]
Number of points
64
64
32
32
Number of points
64
64
32
32
Master station
FX5S CPU module
B0 to B3F
B40 to B7F
B80 to BBF
BC0 to BFF
W0 to W1F
W20 to W3F
W40 to W5F
W60 to W7F
Label name (Station number 2)
G_stlinkIEF.bnRX[H7F]
G_stlinkIEF.bnRY[H7F]
Link device on the servo amplifier side
RX0 to RX3F
RY0 to RY3F
RWr0 to RWr1F
RWw0 to RWw1F
Link device on the servo amplifier side
RX40 to RX7F
RY40 to RY7F
RWr20 to RWr3F
RWw20 to RWw3F
Remote station
MR-JET-G
(Station number 1)
RX0 to RX3F
RY0 to RY3F
RWr0 to RWr1F
RWw0 to RWw1F
Description
Cyclic communication ready
Cyclic communication ready command
3 PROGRAMMABLE CONTROLLER SETTINGS
3.5 Parameter Settings
3
Remote station
MR-JET-G
(Station number 2)
RX40 to RX7F
RY40 to RY7F
RWr20 to RWr3F
RWw20 to RWw3F
28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-jet seriesMelservo-j5 series