Maintenance - Edition 12.2014
– Unscrew the inspection plug -arrow- close to the pendulum
support.
Note
A plastic overflow tube with an 8 mm hexagon socket and a tight‐
ening torque of 3 Nm is located behind this screw. The length of
the overflow tube determines the oil level in the gearbox, when
replacing assign via part number ⇒ Electronic Catalogue of Orig‐
inal Parts .
– Remove overflow tube -arrow-.
Approx. 5.0 ltr of oil flows out. Furthermore, the catch pan remains
under the gearbox.
– Screw overflow tube back in and tighten to 3 Nm.
– Shake the oil reservoir before opening.
Note
The filling hose and adapter -VAS 6262- or -VAS 6262A- must
be clean and gearbox oil must not be mixed with other oils!
Before screwing the adapter for oil filling -VAS 6262A- onto
the oil bottle, measure the length of the ventilation tube, the
dimension -a-, and lengthen off the tube if necessary to the
dimension -a-: Lengthen off 210 mm.
The dimension -a- is measured on the shaft (starting with the
green area in the magnifying glass) of the adapter for oil filling
-VAS 6262A- .
If the thread of the oil bottle does not correspond to the adapter
-VAS 6262A- , the adapter -VAS 6262/6- must be used in ad‐
dition.