6.21 Setting units

Overview
To convert the units 1. Select the desired temperature and volume.

6.22 Backup relay

Description The control board has a spare relay, which allows alternative use in
Locate defective relay
Occupying the spare relay
INFORMATION
Overview
Assigning the backup relay
Canceling the selection Touch the "Back" field.
Relay overview
2. Touch the "OK" field.
case of a relay failure. This is only possible with the listed relays.
Call relay test in the service menu.
Perform relay test. Locate defective relay by examining the
output voltage at the corresponding outputs on the control
circuit board.
Do rewiring according to the table.
Example: When using it for K8 (lift magnet M8), rewire line from
connector X17.1 to X12.5.
In case of changes to the wiring, label or deposit note in the unit.
Select the defective relay by means of the roller.
Touch the "OK" field.
Changes saved.
Service-instructions
Service menu - appliance test