6.23 Settings parameters

6.23.1 Selecting and changing parameters

Description
Overview
Selecting parameters
Changing parameters

6.23.2 Parameter overview

No.
Basic setting
7
User menu password
16
Cooking chamber temperature
offset
21
Core temperature offset,
sensor 1
22
Core temperature offset,
sensor 2
23
Core temperature offset,
sensor 3
24
Core temperature offset,
sensor 4
45
Generator mode
48
Steam elimination mode
49
Controls the cooking chamber
lamp when opening the
cooking chamber door
Querying and setting additional parameters.
Selecting parameters by adjusting the roller.
Tap the "Read" field.
Display of set parameters.
Use the number block to set the desired values by tapping.
Tap the "Write" field.
Changes saved.
Standard
Range of
value
adjustment
111
0 - 300
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
-9.9 - +9.9°K
0
0 = Off
1 = On
1
0 = Low
1 = Normal
2 = High
0
0-60 seconds
Service-instructions
Service menu - appliance test
Explanation
Password for the user menu (basic settings)
Ability to retrieve the saved temperature offset
values. The can also be changed and saved.
The calibration function in the Service menu is
used for calibration!
Only when using generators on ships.
"Low" setting: Minimum water consumption,
but higher condensate temperature and
greater steam volume. "High" setting:
Maximum water consumption, but lower
condensate temperature and smaller steam
volume.
35