7.4 Customize vapour deletion

Description Due to regional regulations, the adjustment of the vestibule removal
Overview
Opening the Service menu 1. Call up the service menu
Selecting parameters 3. Selecting parameters by adjusting the roller.
Changing parameters 5. Use the number block to set the desired values by tapping.
Parameter overview
No.
Basic setting
48
Steam elimination mode
59
Temperature for switching on
vapor quenching
60
Temperature for shutdown
vapor quenching
may be necessary.
Page
14).
2. select "Set parameters".
4. Tap the "Read" field.
Display of set parameters.
6. Tap the "Write" field.
Changes saved.
Standard
Adjustment
value
range
1
0 = Low
1 = Normal
2 = High
140 °F
32 -212 °F
131 °F
32 -212 °F
Service-instructions
Wendy's settings
(see „6.1.1 Calling up the service level‟,
Explanation/ instruction
Set parameter to "2".
Set temperature to 131°F.
Set temperature to 140°F.