4.2

Reversing boiler door

The burner door is factory-fitted with the hinges on the right – the burner
door opens to the right.You can change the burner door hinges over to
the left-hand side if desired to suit the installation site.
Remove the burner hood/burner door panel first
( Chapter 3.1, page 12).
▶ Removing the burner door ( Chapter 3.1, page 12).
▶ Unscrew the hinge bolts and remove the hinges.
▶ Mount the hinges on the left-hand side of the boiler using the hinge
bolts.
1 2
Fig. 8
Reversing the burner door (boiler heat exchanger attachments)
[1]
Hinge bolts
[2]
Hinges
Logano G115 WS US/CA – 6 720 813 418 (2019/09)
▶ First remove the hinge lobe bolts and then the hinge lobes. Mount the
hinge barrels on the left-hand side of the boiler using the hinge-barrel
bolts.
▶ Hook the burner door with the hinge lobes onto the hinges.
▶ Check that the heat exchanger baffles are placed horizontally
( Chapter 6.3, page 29).
▶ Close the burner door and secure with the two hexagon-head
bolts.Tighten the hexagon-head bolts evenly (approx. 90 Lbs/inch)
so that the burner door seals properly.
2
2 1
7 747 019 141-08.1RS
Fig. 9
[1]
Hinge-barrel bolts
[2]
Hinge lobes
[3]
Burner door
[4]
Hinges
[5]
Heat exchanger baffle plates
Installing the boiler
If the burner door hinges have been changed over to the
left-hand side, the burner cable must be disconnected
from the burner before opening the burner door.
3
1
4
Reversing the burner door (door attachments)
4
5
7 747 019 141-09.1RS
15