5.8.3

Connecting the power supply and additional components

Establish a permanent connection to the mains power supply in
accordance with the locally applicable regulations.
WARNING: Fire hazard from hot boiler components.
Hot boiler components may damage electrical cables.
▶ Ensure that all wiring is routed in the ducts provided
or on the boiler insulation.
▶ Route all cables through the cable entries to the control panel and
connect in accordance with the wiring diagram.
5.8.4

Fitting cable ties

Secure all cable runs with cable ties (included with the control):
▶ Insert the cable ties together with the cable from the top into the slots
in the frame (step 1).
▶ Slide the cable ties downward (step 2).
▶ Push against the ties (step 3).
▶ Flip the toggle up (step 4).
Fig. 24 Securing cables with cable ties
Logano G115 WS US/CA – 6 720 813 418 (2019/09)
5.9

Fitting outer casing panels

▶ Position and secure the control device cover.
▶ Fit the rear boiler cover.
▶ Secure by reinstalling cover screws and jacket panel screws.
Fig. 25 Fitting the rear boiler cover
[1]
Controls cover
[2]
Rear boiler cover
7 747 019 141-25.1RS
5
Installing the boiler
27