6 INSTALLATION

6.1 ELECTRICAL CONNECTION

The terminal indicated by this
symbol
nents together that are normally
earthed. Connect the appliances
appropriately using this terminal in
order to make sure that they are
equipotential.
If the phase voltage drops below
190V~, the performance of the
oven may suffer, not due to the
product itself.
GENERAL INFORMATION
Make sure that the characteristics of the
mains power supply are compatible with
the data indicated on the plate. The iden-
tification plate bearing the technical data,
serial number and brand name is placed in
a visible position on the appliance. Do not
remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The appliance is provided with a five-core
H07RN-F cable (5 x 2.5 mm² referring to
the cross section of the internal conductor).
52
Installation
connects compo-
6.2 CONNECTING TO THE
MAINS POWER SUPPLY
• The appliance should only be connected
to the mains power supply by a quali-
fied technician and in compliance with
current plant safety regulations.
• Before connecting to the mains power
supply, make sure that:
- the supply voltage and frequency
correspond to those indicated on the
identification plate
- the electrical system is suitable for the
power required by the appliance and
indicated on the identification plate on
the oven
- the electrical system is fitted with an
earth connection in compliance with
current regulations
- there is a disconnect device between
the appliance and the mains power sup-
ply with a minimum contact separation in
overvoltage category III. The disconnec-
tor must be suitable for the electrical load
of the appliance and comply with current
regulations
- the disconnect device is clearly indicat-
ed and easily accessible after the appli-
ance is installed. Under no circumstances
should the earth conductor (yellow/
green conductor) be interrupted by the
protection and isolation devices.
• The appliance must be connected to an
equipotential system, the effectiveness
of which must be ascertained according
to current regulations. The equipotential
bonding terminal is located at the back
of the appliance.
• The appliance is fitted with a power
cable connected to the internal terminal

Advertisement