Installation Instructions - Smeg H05RR-F Manual

Table of Contents

Advertisement

IMPORTANT - This appliance is easy to use.
However, to obtain the best results it is important
to read this handbook carefully and follow all the
instructions before putting your oven into
operation.
This handbook supplies correct instructions for
installation, use and maintenance, as well as useful
advice and safety warnings.
Keep this handbook in a safe place for future
reference.
If you sell or pass on your oven, make sure that
this handbook goes with it.
The appliance must be installed by qualified staff in
accordance with the manufacturer's instructions.
Incorrect installation may cause injury or damage, for
which the manufacturer cannot be considered
responsible.
Never leave packaging components such as nails,
expanded polystyrene, straps, etc. within the reach of
children, since they may be dangerous.
The appliance's electrical safety is only assured if it is
correctly connected to an efficient earth system.
Check that this safety requirement is met, and if in
doubt ask a qualified electrician to thoroughly check
the system.
The appliance must only be used for the purpose for
which it is intended. All other uses (such as room
heating) must be considered improper and thus
dangerous.
Do not obstruct openings, nor the ventilation or heat
dispersion vents.
Always check that the control knobs are on zero (off)
when the oven is not in use.
Installation instructions
Important
- The oven must be installed by an
specialized technician in accordance with the
regulations in force.
Any adjustments, maintenance, etc. must be carried
out with the appliance disconnected from the electricity
supply.
Electrical connection
Check to make sure that the voltage and the power
supply line ratings are the same as those given on the
rating plate under the appliance.
The mains supply line is not supplied.
Use a H05RR-F - H05RN-F type cord remembering that
the end that goes on the appliance must have the earth
wire (yellow-green) at least 20 mm. longer.
When the worktop is installed, the mains supply line
should be equipped with a multi-pole switch with a
contact opening of at least 3 mm.. The switch should
be close to the cooktop and easily accessible.
The possibilities for electrical network connection are
indicated in the following table. If necessary, modify the
position of the terminal board bridges.
Section
Cord H05RR-F - H05RN-F
230V~
400V 2N~
400V 3N~
Section en mm2
mm
5 x 1,5
Connection table
1
2
3 4
5
1
2
3 4
5
1
2
3 4
5
R!
IRS
?
<j)
0-<j> (j^-O
'
TT+jp
R
S (N)
230V ~
R
S
N
400V 2N
R S
T
N
400V 3N