INSTALLATION

Electrical connection

See General safety instructions.
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
• 220-240 V~
3 x 1.5 mm² three-core cable.
The values indicated above refer to the
cross section of the internal lead.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
91477A524/E
3. Replace the bulb (B) with one of the same
type (25 W). Use only oven bulbs (T
300°C).
4. Re-fit the bulb protector (A).
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Connection with plug and socket
Make sure that the plug and socket are of the
same type.
Avoid using adapters, gang sockets or shunts as
these could cause overheating and a risk of
burns.
Cable replacement
Power voltage
Danger of electrocution
• Disconnect the mains power supply.
1. Unscrew the rear casing screws and remove
the casing to access the terminal board.
A = position of the power cable
2. Replace the cable.
3. Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the appliance.