Advanced Management Module Error Messages - IBM BladeCenter PN41 Problem Determination And Service Manual

Deep packet inspection blade
Table of Contents

Advertisement

Advanced management module error messages

Power to the DPI blade is provided by shared BladeCenter unit resources. See the
following table and "Solving shared BladeCenter resource problems" on page 58.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 3020," on page 23 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
VRD Power Good fault
System under or over recommended voltage
for xx.
System over temperature for xx component
52
IBM BladeCenter PN41 Type 3020 Deep Packet Inspection Blade: Problem Determination and Service Guide
Action
1. Reseat the DPI blade.
2. Check the function of the shared BladeCenter unit resources. See
"Solving shared BladeCenter resource problems" on page 58 for
more information.
3. Replace the DPI blade.
1. Reseat the DPI blade.
2. Check the function of the shared BladeCenter unit resources (see
"Solving shared BladeCenter resource problems" on page 58).
3. Refer to the following voltages table for more information.
4. If the problem persists, call for service.
1. Reseat the DPI blade.
2. Check the function of the shared BladeCenter unit resources (see
"Solving shared BladeCenter resource problems" on page 58).
3. See the following temperature table for more information.
4. Replace the DPI blade.
Table 3. Temperature (°C)
Component
BACN temperature
BACS temperature
Base temperature 1
Base temperature 2
PSWX Temperature
IXP2805
Temperature
Table 4. Voltages
Source
BACN Vcc Aux 2.5
BACN Vcc Int 1.0
BACN Vrefp 2.5
BACS Vcc Aux 2.5
BACS Vcc Int 1.0
BACS Vrefp 2.5
Base Vcc 1.0 V
Value
Warning
48.11
75.69
54.02
75.69
32.00
60.00
33.00
60.00
52.05
75.69
52.05
75.00
Value
+2.49
+0.99
+2.49
+2.50
+1.00
+2.49
+1.01
Hard shutdown Warning reset
87.51
65.84
87.51
65.84
70.00
55.00
70.00
55.00
87.51
65.84
85.00
65.00
Critical
(+2.37 , +2.62)
(+0.94 , +1.05)
(+2.44 , +2.55)
(+2.37 , +2.62)
(+0.94 , +1.05)
(+2.44 , +2.55)
(+0.94 , +1.05)

Advertisement

Table of Contents
loading

This manual is also suitable for:

3020

Table of Contents