IBM BladeCenter PN41 Problem Determination And Service Manual page 58

Deep packet inspection blade
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 3020," on page 23 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
ID
Message
3
Link loop back - Network
48
Configuration Manager
Information Configuration
49
Configuration Manager Error
Configuration
50
Backup Manager Information
Configuration
51
Backup Manager Error
Configuration
52
Resource monitor - Software
133
SFP Mismatch - Hardware
150
FPGA Error - Hardware
612
Resource monitor -
Hardware
693
SFP Mismatch OK -
Hardware
710
FPGA - Hardware
5550
Flow Control Disabled -
Network
5551
Flow Control Enabled to
TRANSMIT - Network
46
IBM BladeCenter PN41 Type 3020 Deep Packet Inspection Blade: Problem Determination and Service Guide
When/why it
Severity
Occured
Informational
A link loopback
condition is
detected in a port.
Informational
ASM and DPPM
configuration
Critical
ASM and DPPM
configuration
Informational
ASM backup and
restore operations
Minor
ASM backup and
restore operations
Minor
ASM
maintenance
tasks are
completed (such
as log file
rotation).
Major
The SFP plugged
in the capture
port is not
compatible with
the version of
CPOS.
Critical
A discrepancy
detected in the
image of an
FPGA
Informational
ASM disk space
or memory is low.
Informational
The correct SPF
module is
plugged into the
capture port.
Informational
FPGA upgrade is
progressing.
Informational
Operator
configured Flow
Control to
Disabled for the
specified port.
Informational
Operator
configured Flow
Control to
Transmit Only for
the specified port.
Action
Set loopbacks only for special test
conditions
N/A
Check consistency of the configuration.
Message is for informational purposes only.
1. Redo backup operation.
2. If the problem persists, call for service.
Message is for informational purposes only.
1. Replace the SFP module.
2. If the problem persists, call for service.
Update the FPGA.
Message is for informational purposes only.
Message is for informational purposes only.
Message is for informational purposes only.
Message is for informational purposes only.
Message is for informational purposes only.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3020

Table of Contents