7303
HeartBeat Monitor generic
error - Software
7304
Module unequipped -
Hardware
7305
FastPath Ingress down -
Hardware
7306
FastPath Engress down -
Hardware
7307
Module failure - Hardware
48
IBM BladeCenter PN41 Type 3020 Deep Packet Inspection Blade: Problem Determination and Service Guide
When/why it
Severity
Occured
Critical
The heartbeat
process detects
that the blade is
no longer
optional. This
error clears
automatically if
the heartbeat
process detects
that the blade is
operation again.
Critical
The DPI blade is
removed from the
BladeCenter unit.
Critical
Internal DPPM
hardware busses
failed to
synchronize.
Critical
Internal DPPM
hardware buses
failed to
synchronize.
Critical
Internal DPPM
hardware failure
detected.
Action
1. Make sure that the control network is
running.
2. Make sure the DPI blade is receiving
power.
3. Check the binding parameters.
4. Turn off the DPI blade. Turn on the DPI
blade.
1. Reseat the blade in the BladeCenter
unit.
2. Make sure that the control network is
running.
3. Make sure the DPI blade is receiving
power.
4. Check the binding parameters.
5. Turn off the DPI blade. Turn on the DPI
blade.
1. Check the control communication link.
2. Turn on the DPI blade and attempt to
run an application.
3. If the problem persists, call for service.
1. Check the control communication link.
2.
Turn on the DPI blade and attempt to
run an application.
3. If the problem persists, call for service.
1. Use the show techsupport all CLI
command to create a report, then call
for service. See the CloudShield
Command Line Interface Users Guide
on the IBM BladeCenter PN41
Documentation CD.
2. If the application is critical; then, turn off
the DPI blade.