F-61
5VDC SUPPLY MODULE REMOVAL AND REPLACEMENT PROCEDURE
REPLACEMENT PROCEDURE
1. Replace the 5VDC Supply Module.
2. Secure the new Supply Module to the DIN rail.
3. Connect all previously removed leads to their
proper locations on the Supply Module.
4. Perform the Case Cover Replacement
Procedure.
5. Perform
the
Replacement Procedure.
6. See Retest After Repair.
All manuals and user guides at all-guides.com
TROUBLESHOOTING AND REPAIR
(continued)
FIGURE F.24 – 5 VOLT SUPPLY LEAD LOCATIONS
81
81 50 50
+ + - -
5VDC/5A
DC ON
DPP25-5
N L
Ground
102A
(Green)
(White)
Monitor
and
Pedestal
VRTEX
+ + - -
+ + - -
15VDC/3.4A
15VDC/3.4A
DC ON
DC ON
DPP50-15
DPP50-15
N L
N L
103B
(Pink/Red)
TM
360