INVERTEC
V160-S, V160-T & V160-TP
OPERATOR'S MANUAL
ENGLISH
Lincoln Electric Bester Sp. z o.o.
ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland
www.lincolnelectric.eu

Advertisement

loading

Summary of Contents for Lincoln Electric INVERTEC V160-TP

  • Page 1 IM2007 05/2016 REV06 ® INVERTEC V160-S, V160-T & V160-TP OPERATOR’S MANUAL ENGLISH Lincoln Electric Bester Sp. z o.o. ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland www.lincolnelectric.eu...
  • Page 2 EN 60974-1:2012; EN 60974-10:2014 (EN 60974-3:2014 only for –T/-TP) 20.04.2016 Piotr Spytek Operations Director Lincoln Electric Bester Sp. z o.o., ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland English English...
  • Page 3: Table Of Contents

    12/05 12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code & Serial Number can be found on the machine rating plate.
  • Page 4: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 5: Installation And Operator Instructions

    WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION: Remove fire hazards from the welding area and have a fire extinguisher readily available. Welding sparks and hot materials from the welding process can easily go through small cracks and openings to adjacent areas. Do not weld on any tanks, drums, containers, or material until the proper steps have been taken to insure that no flammable or toxic vapors will be present.
  • Page 6 ARFU (Auto-Restore FUse) and switch to remote control mode. More information on The dual input voltage machine is provided with the this mode of operation will be given in the next section. ARFU device. It operates only when the input is connected to the 115Vac mains and protects from input Controls and Operational Features overcurrent.
  • Page 7 G. Thermal LED: This indicator will turn on when the machine is overheated and the output has been disabled. This normally occurs when the duty cycle of the machine has been exceeded. Leave the machine on to allow the internal components to cool. When the indicator turns off, normal operation is again possible.
  • Page 8 M. Postflow Control (V160-T machines only): In the TIG TIG Trigger Sequences welding modes, this control knob will adjust the TIG welding can be done in either the 2-step or 4-step shielding gas postflow time from 0.5 to 30 seconds. mode.
  • Page 9 The machine will now maintenances, it is recommended to contact the nearest decrease the output current at a controlled rate, or Technical Service Center or Lincoln Electric. Repairs downslope time, until the Crater current is reached. and modifications performed by unauthorized service or This Crater current can be maintained as long or as personnel will cause, that the manufacturer’s warranty...
  • Page 10: Electromagnetic Compatibility (Emc)

    WARNING Do not touch electrically live parts. WARNING Before the case of welding machine will be removed, the welding machine had to be turned off and the power lead had to be disconnected from mains socket. WARNING Mains supply network must be disconnected from the machine before each maintenance and service.
  • Page 11: Technical Specifications

    Technical Specifications V160: INPUT EMC Group / Input Voltage Input Power at Rated Output Frequency Class 230V  15% 5.4kW @ 100% Duty Cycle 50/60 Hz 7.0kW @ 35% Duty Cycle Single Phase II / A RATED OUTPUT AT 40°C Duty Cycle Output Current Output Voltage...
  • Page 12: Weee

    12/05 Part list reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.