Fault Messages
Table 1-8 Examples of Fault Occurrence Display Using
Fault
Alarm
Date
26
MN
99/01/08 13:28
26
MN
99/01/08 13:28
26
MN
99/01/08 13:28
27
MN
99/01/08 13:27
27
MN
99/01/08 13:27
28
MN
99/01/08 13:28
2B
MN
99/01/08 13:27
2B
MN
99/01/08 13:27

Table 1-9 Example of Fault Restoration Display Using MATWorX

Fault
Alarm
Date
18
-
99/01/08 13:26
19
-
99/01/08 13:26
19
-
99/01/08 13:26
19
-
99/01/08 13:26
30
-
99/01/08 13:28
30
-
99/01/08 13:28
Page 26
MATWorX or MATWorX Studio (Continued)
CPU
FP 1
DLC card down
DLC Failure Kind : Terminal failure (Station number = 2000)
Data = (05 00 80 20 00 FF FF FF)
FP 1
DLC card down
DLC Failure Kind : Terminal not connected (Station number = 2000)
Data = (06 00 80 20 00 FF FF FF)
FP 1
DLC card down
DLC Failure Kind : Terminal circuit failure (Station number = 2000)
Data = (08 00 80 20 00 FF FF FF)
FP 0
Synchronism of DPC missed
DPC on the side of a partner (DPC Number = 0001FFFF)
Data = (00 00 01 FF FF FF FF FF)
FP 0
Synchronism of DPC missed
DPC on the side of oneself (DPC Number = 0005FFFF)
Data = (01 00 05 FF FF FF FF FF)
AP
SMDR output buffer memory overflow
(Memory Kind = 00 Overflow kind : External relay turns ON and OFF)
10
Data = (00 00 FF FF FF FF FF FF)
MP
CS/ZT fault occurred
Fault kind : CS/ZT connection down (CS/ZT No. = 10)
Data = (00 04 00 10 31 01 FF FF)
MP
CS/ZT fault occurred
Fault kind : CS/ZT carrier has no space (CS/ZT No. = 10)
Data = (01 04 00 10 FF FF FF FF)
CPU
MP
FP/AP card returned to normal condition
(FP/AP NO. = 52)
Data = (F4 FF FF FF FF FF FF FF)
MP
Power failure returned to normal condition
Recover Kind : AC input failure
Data = (00 01 02 FF FF FF FF FF)
MP
Power failure returned to normal condition
Recover Kind : fuse break
Data = (01 02 00 FF FF FF FF FF)
MP
Power failure returned to normal condition
Recover Kind : PWR alarm
Data = (02 00 01 FF FF FF FF FF)
AP 5
DTI line returned to normal condition
PCM loss
Data = (F0 FF FF FF FF FF FF FF)
AP 5
DTI line returned to normal condition
Frame loss
Data = (F1 FF FF FF FF FF FF FF)