NEC NEAX 2000 IVS2 Maintenance Manual page 105

Integrated voice server
Hide thumbs Also See for NEAX 2000 IVS2:
Table of Contents

Advertisement

Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
RUN lamp is not
PN-30CCTA (CCT)
flashing
LC lamp is not on
PCM lamp is on
FRM lamp is on
MFRM lamp is on
RMT lamp is on
MRMT lamp is on
AIS lamp is on
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
LAMP STATUS
Abnormal operation
of CCT card
Common signaling
channel data link
connection failure
No PCM signals
arrive from the
distant office
Frame Alignment
signals from the
distant office cannot
be received
Multi-Frame
Alignment signals
from the distant
office cannot be
received
Frame Alignment
signals cannot be
sent to the remote
PBX
Multi-Frame
Alignment signals
cannot be sent to
the remote PBX
Remote PBX is in
local loop-back
state
CHAPTER 2 TROUBLESHOOTING
FAULT
CONTENT
1
Confirm the programming data: CM05
Y=0/Y=1, CM07 YY=01.
2
Check to see if the SENSE switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05 Y=0.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
Check the local office line or public network
line.
1
Check to see if the line is correctly
connected to the CCT card.
2
Plug and unplug the CCT card.
Repeat this two or three times.
1
Check the receive line and external
equipment.
2
Replace the remote CCT card.
1
Check the receive line and external
equipment.
2
Replace the remote CCT card.
1
Check the transmission line and
external equipment.
2
Replace the CCT card.
1
Confirm the switch setting on the CCT
card indicating an alarm.
2
Replace CCT card not indicating an
alarm, with a spare.
Check the switch settings of the remote
CCT card.
Fault Diagnosis and Troubleshooting
REMEDIAL ACTION
Page 97