NEC NEAX 2000 IVS2 Maintenance Manual page 120

Integrated voice server
Hide thumbs Also See for NEAX 2000 IVS2:
Table of Contents

Advertisement

CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-4RSTB
RUN lamp is not
(MFR)
flashing
PN-4RSTC
RUN lamp is not
(CIR)
flashing
PN-SC00
RUN lamp is not
(CCH)
flashing
LC lamp is not on
Page 112
LAMP STATUS
Abnormal operation
of MFR card
Abnormal operation
of CIR card
Abnormal operation
of CCH card
CCH link
connection failure
FAULT
CONTENT
1
Confirm the programming data: CM05
Y=0.
2
Check to see if the SENS switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05 Y=0.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Confirm the programming data: CM05
Y=0.
2
Check to see if the SENSE switch is set
as per the AP Number (04-15)
assigned by CM05 Y=0.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Confirm the programming data: CM05
Y=0.
2
Check to see if the SENS switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05 Y=0.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
Check the status of the local-office side line
or the remote-office side line.
REMEDIAL ACTION
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0

Advertisement

Table of Contents
loading

Table of Contents