CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
: System Initialization information
c
The address of the program which caused system initialization.
: Communication Failure Kind
d
00: Overflow of data sending buffer to the FP/AP .
01: Invalid data received from FP/AP
: FP/AP Number
e
00-03, 17-19: FP No. 0-3, 17-19
04-15, 20-31: AP No. 4-15, 20-31
: Power Failure Kind
f
00: AC input failure
01: Fuse break
02: PWR alarm
g
: Fault Kind
00: Fault notice from CS/ZT
01: CS/ZT initial failure
02: CS/ZT condition read failure
03: CS/ZT condition unmatch
04: B-Channel condition unmatch
05: SYS-ID upload failure
06: SYS-ID download failure
07: CS/ZT make busy failure
08: CS/ZT data load failure
09: B-Channel make busy failure
0A: CS/ZT operation parameter change failure
0B: LCCH sending position failure
0C: Carrier selection failure [North America/Latin America Only]
0D: CS/ZT expansion data read failure
0E: CS/ZT expansion data setting failure
0F: CS/ZT operation Parameter 2 change failure
: AP No. of CS/ZT fault occurred 04-15, 20-31
h
: CS/ZT Interface No. of fault occurred 000-255
i
: Inspection Kind
j
00: Battery check
: Power Failure Restoration Kind
k
00: AC input failure
01: Fuse break
02: PWR alarm