CHAPTER 2 TROUBLESHOOTING
Fault Diagnosis and Troubleshooting
Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-DAIB
RUN lamp is not
(DAIB)
flashing
LINK lamp is not on
RED lamp is on
RMT lamp is on
Page 100
LAMP STATUS
Abnormal operation
of DAIB card
Layer 2 link
connection failure
between DAIA and
DAIB
PCM signal loss or
Frame Alignment
signal loss
Remote alarm
FAULT
CONTENT
1
Reset the MB switch.
(Down→Up→Down)
2
If the fault cannot be cleared, replace
the card.
1
Check to see if the cable between DAIA
and DAIB is correctly connected.
2
Reset the MB switch.
(Down→Up→Down)
1
Check to see if the cable between DAIA
and DAIB is correctly connected.
2
Reset the MB switch of DAIA card on
the main site.
(Down→Up→Down)
Check to see if the cable between DAIA and
DAIB (sending side) is correctly connected.
REMEDIAL ACTION