Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-IPTB
LINK lamp is not on
(IPT)
[PZ-M567]
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
LAMP STATUS
LAN connection
failure
CHAPTER 2 TROUBLESHOOTING
FAULT
CONTENT
1
Check to see if the LAN cable is
correctly connected.
2
Confirm the condition of the LAN
device connected to the IPT.
(ex. Power of HUB)
3
Confirm whether the MODE switch is
set to 0.
4
When the fault cannot be cleared
by
and set the baud (100 Mbps or 10
Mbps) by the SW2-1 switch according
to the LAN device.
5
If the fault cannot be cleared, replace
the card.
Fault Diagnosis and Troubleshooting
REMEDIAL ACTION
1
3
to
above, set the MODE to 1,