CHAPTER 1 MAINTENANCE SERVICE FEATURES
Fault Messages
(2) To clear the MJ/MN alarm by external key:
START
Assign the card number for External
CM10
Key Interface (PN-DK00) to the
desired LEN.
NOTE 1: The card number of the
NOTE 2: Circuit No. 3 of E963 is used
Assign the function of MJ/MN alarm
CM61
clear key to the external key.
END
(3) To set Alarm Kind of Fault Information via MATWorX:
Please consult the Online Help included with MATWorX.
NOTE 1: CM08>450, 451 cannot be set by MATWorX.
NOTE 2: Some Standard settings of the fault kind cannot be changed by MATWorX.
Page 10
DESCRIPTION
External Key Interface (PN-
DK00) must be assigned to
the first LEN (LEVEL 0) and
third LEN (LEVEL 2) of each
card slot.
for built-in External Key
Interface of MP card by
setting CM61.
DATA
(1)
000-763: LEN
(2)
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For PIM0/1: E900-E915
For PIM2/3: E916-E931
For PIM4/5: E932-E947
For PIM6/7: E948-E963
YY=30
(1)
XX Z
XX : 00-63 : Card No. of PN-DK00
Z
: 0-3
: Circuit No.
633 : MP built-in External Key Interface
(2)
00 : MJ/MN alarm clear key
NEAX2000 IVS
2
Maintenance Manual