Table 2-6 Remedial Action on Each Lamp Status (Continued)
CARD NAME
PN-2BRTK (BRT)
RUN lamp is not
flashing
ALM1 lamp is on
ALM0 lamp is on
PN-CC01 (ETHER)
RUN lamp is not
flashing
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0
LAMP STATUS
Abnormal operation
of BRT card
No. 1 circuit
transmission line
fault
No. 0 circuit
transmission line
fault
Abnormal operation
of ETHER card
CHAPTER 2 TROUBLESHOOTING
FAULT
CONTENT
1
Confirm the programming data: CM05.
2
Check to see if the SENSE switch is set
as per the AP Number (04-15, 20-31)
assigned by CM05, CM07 Y=2.
3
Reset the MB switch.
(Down→Up→Down)
4
If the fault cannot be cleared, replace
the card.
1
Confirm No. 1 circuit line status.
2
Confirm PSTN line status.
1
Confirm No. 0 circuit line status.
2
Confirm PSTN line status.
Replace the ETHER card.
Fault Diagnosis and Troubleshooting
REMEDIAL ACTION