CHAPTER 1 MAINTENANCE SERVICE FEATURES
Diagnostics
Programming Procedure
No programming is required.
Operating Procedure
(1) Station Status Information
Operation:
F50
0 + X-XXXXXXXX
(STATION NO.)
OR
0 + FX-FXXXXXXXX
term
(D
NO.)
For the meaning of status code, see
STATUS
CODE
01
Idle
02
In Line Lockout mode
10
Dialing to an ORT
11
Dialing to a trunk
12
Dialing to an ORT (After consultation hold a station)
13
Dialing to an ORT (After consultation hold a trunk)
14
Dialing to a trunk (After consultation hold a station)
15
Dialing to a trunk (After consultation hold a trunk)
1F
Dialing to an ORT (After consultation hold 3-party Conference Trunk)
20
In Reorder Tone connection
Page 36
ST
COMMAND=
+
DE
F50>
+
DE
XXXX : XX XX XX XX
Table
Table 1-11 Station Status Information
DESCRIPTION
STATUS CODE OF THE DESIGNATED ADDRESS +3
STATUS CODE OF THE DESIGNATED ADDRESS +2
STATUS CODE OF THE DESIGNATED ADDRESS +1
STATUS CODE OF THE DESIGNATED ADDRESS
DESIGNATED ADDRESS
1-11.
REMARKS
2
NEAX2000 IVS
Maintenance Manual
ND-70926 (E), Issue 3.0