ICP-X1000 series 24-button cross-point control
block
1 to 23 (1st button number: unshifted state)
24 to 46 (2nd button number: shifted state)
Number 1 (unshifted)
Number 24 (shifted)
Cross-point control block
Each cross-point button has two button numbers, and you
use the [SHIFT] button to switch between these numbers.
In a 36-button row, the button numbers are as follows.
Button
Button number
when the [SHIFT]
button is off
1st (left side) to
1 to 35
35th buttons
In a 24-button row, the button numbers are as follows.
Button
Button number
when the [SHIFT]
button is off
1st (left side) to
1 to 23
23rd buttons
The rightmost (36th/24th) button is used as the [SHIFT]
button.
When selecting the signal of button numbers 1 to 35/1 to
23, press the corresponding number button.
When selecting the signal of button numbers 36 to 70/24
to 46, press the [SHIFT] button, turning it on, and press
the corresponding number button.
[SHIFT] button
The [SHIFT] button has two operation modes.
Hold mode: Mode where the shifted state is selected
while the button is pressed
Lock mode: Mode where every time the button is pressed,
it toggles between the shifted state and unshifted state
You can also disable the shift button function.
For details, see "Setting the Shift Button" (page 380).
SHIFT button
Number 23 (unshifted)
Number 46 (shifted)
Button number
when the [SHIFT]
button is on
36 to 70
Button number
when the [SHIFT]
button is on
24 to 46
88
Notes
• The operation mode of the [SHIFT] button is the
operation mode set by the cross-point assign table of the
switcher bank, regardless of the buses assigned to the
cross-point button rows.
• The rightmost button operates as a cross-point button
when the [SHIFT] button use is disabled.
In a 36-button row, it becomes button number 36. In a
24-button row, it becomes button number 24.
[SHIFT ALL] button
You can switch all the cross-point buttons in the 1st row
to 4th row to the shifted state using the [SHIFT ALL]
button assigned to the cross-point pad/function button
section (excluding 1st row delegation buttons in key/
AUX bus delegation mode).
The [SHIFT ALL] button operation can be set to hold
mode or lock mode.
Notes
• The [SHIFT ALL] button is enabled, even if the
[SHIFT] button use is disabled.
The button numbers are as follows.
– 36-button row: 1 to 36 (unshifted state) to 37 to 72
(shifted state)
– 24-button row: 1 to 24 (unshifted state) to 25 to 48
(shifted state)
• The [SHIFT ALL] button is disabled in the following
cases.
– In [SHIFT] button hold mode
– When dual background bus mode is set
– When dual M/E is set
AUX bus control block
Each cross-point button and delegation button has two
button numbers, and you use the [SHIFT] button to
switch between these numbers.
When second delegation mode is enabled
In a 36-button row, the button numbers are as follows.
Button
Button number
when the [SHIFT]
button is off
1st (left side) to
1 to 35
35th buttons
The rightmost (36th) button is used as the [SHIFT]
button.
When selecting the bus/signal of button numbers 1 to 35,
press the corresponding number button.
When selecting the bus/signal of button numbers 36 to 70,
press the [SHIFT] button, turning it on, and press the
corresponding number button.
Button number
when the [SHIFT]
button is on
36 to 70