Maintenance
[Analog/ NXDN/ DMR]
Allows you to display the signal strength and Bit Error Rate (BER) on the LCD
when constructing the system or during maintenance.
1
PF Button:
Press the programmed button to enter Maintenance Display Mode.
Menu Mode:
Select "MAINT" and press the [ S ] button to enter Maintenance Display Mode.
2
Press the [ <B ] and [ C> ] buttons to select Signal strength (RSSI Level) or
BER.
BER display is available on NXDN/ DMR channel.
When the signal strength is less than -120 dBm, "
When BER measurement is impossible, "
3
Press the [ S ] button to confirm and exit mode.
Signal strength (RSSI Level: dBm)
Bit Error Rate
48
" is displayed.
" is displayed.