7.1 SET-UP (
Set-up
During first start-up, the functions/parameters listed below must be set or adjusted:
Dishwasher parameter modification procedure
With the tank empty
1- Switch the appliance on; the display will show "FILL" and
filling will start.
2- Open the door/lift the hood (depending on the model);
"CLOSE" will appear on the display
3- Press the
button and hold it down for 5/7 seconds.
When -------- appears on the display, release the button and
press it again to access the main PCB setup menu.
With the tank full/the hood open
1 - Press the
button and hold it down for 5/7 seconds.
When -------- appears on the display, release the
and press it again to access the main PCB setup menu.
All the modifiable parameters can now be displayed, scrolling through them with the
Press the
button to select the value required for each parameter.
To confirm the value required simply quit the menu or move on to the next parameter by pressing
Quitting the setup menu automatically: wait about 3 minutes without using the controls.
Quitting the setup menu in manual mode: hold the ON/OFF button until the beep sounds; the dishwasher
switches off.
When the display control panel is switched on, the display
shows the type of dishwasher (PRF 400, PRF 500,
CAPOTE.......), followed by the firmware version and
If the dishwasher is already powered up, press the on/off
button for direct display of the firmware version and
)
button
14
update installed.
update installed.