Omron V680 Series User Manual page 83

Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

 V680-D1KP66T
 Mounting on Non-metallic Material
Mount the RF Tag using M3 flat-head screws
from the marked side.
Tighten the screws to a torque of 0.3 to 0.5 N·m.
 Mounting on Metallic Material
The communications range will decrease if there
is metal at the back of the V680-D1KP66T RF
Tag.
If the RF Tag is mounted on metallic material,
use the V600-A86 Attachment (sold separately)
or a non-metallic spacer (e.g., plastic or resin).
Refer to RF Tag Installation Precautions in Section 11 Appendices for information on the effect of metal at the back surface,
Mutual Interference of RF Tags and Influence of Inclination of the V680-D1KP66T.
p.283
Installation and Connections
Mounting Hole Dimensions
M3 flat-head screw
25
±0.2
Marked side
M3 flat-head screw
Mounting Hole Dimensions
Marked side
25
±0.2
Attachment (V600-A86)
Section 4
Two, M3 holes
25
±0.2
Two, M3 holes
25
±0.2
RFID System
User's Manual
(Modbus TCP)
81