Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

 Error End
Byte 0
Byte 1
Byte 2
Transaction
Protocol identifier
identifier
Copy of the transaction
Always 0000 hex
identifier that was specified
in the query
Transaction Identifier
A copy of the value that was specified in the query is returned.
Protocol Identifier
This field is always 0000 hex.
Field Length
The number of bytes inclusively from the unit identifier through the end of the data is specified.
Byte 4 will always be 00 hex.
Unit Identifier
This field is always FF hex.
Function Code
A value of 80 hex is added to the value that was specified in the query and set.
Exception Code
A code that provides information on the error is attached.
Exception code
01 hex
Illegal function
02 hex
Illegal data address
03 hex
Illegal data value
04 hex
Failure in slave device
06 hex
Slave device busy
Byte 3
Byte 4
Byte 5
Field length
identifier
Always
No. of
Always
00 hex
bytes
FF hex
Range specified with the field length
Meaning
Host Communications Specifications
Byte 6
Byte 7
Byte 8
Unit
Function
Exception
code
code
Section 7
RFID System
161
User's Manual
(Modbus TCP)