Parameter
Communicati
Diagnostic result
ons
diagnostic
information
Send power level
Receive power
level
Noise level
Power level
Tag ID data
Reserved
Error Response
Byte 0
Byte 1
Byte 2
Transaction
Protocol identifier
identifier
X
X
0000 hex
Parameter
Exception code
For details, refer to Exception Code Table in this section.
Contains the result for communication diagnostic in 4-digits hexadecimal.
0000 hex : Normal communications
0001 hex : Insufficient power to send
0002 hex : Insufficient power to receive
0003 hex : Too much noise
0004 hex : Insufficient signal-to-noise ratio.
• The value is 0000 hex (fixed) when the communications result shows normal
communications.
• If a communications precaution is given for the communications result, the result
indicates the cause.
Contains the send power level for communication diagnostic in 4-digits hexadecimal.
0 to 10
• This is the corrected lowest value of DAC (10-bit) where communications with the RF Tag
were successful out of the multiple send power levels.
• The value is 0000 hex (fixed) when the communications result shows an RF Tag missing
error.
Contains the receive power level for communication diagnostic in 4-digits hexadecimal.
0 to 10
• This is the corrected ADC (10-bit) value for response communications with the RF Tag.
• The value is 0000 hex (fixed) when the communications result shows an RF Tag missing
error.
Contains the noise level for communication diagnostic in 4-digits hexadecimal.
0 to 10
• This is the corrected ADC (10-bit) value before communications with the RF Tag were
executed.
Contains the power level for communication diagnostic in 4-digits hexadecimal.
0 to 10
• This parameters contains the overall value of the send and receive power levels
calculated with the following formula.
(Send power level + Receive power level)/2
Contains the Tag ID data of the recognized RF Tag for communication diagnostic in 16-
digits hexadecimal.
• The value is 0000000000000000 hex (fixed) when the communications result shows an
RF Tag missing error.
0000 hex (fixed)
Byte 3
Byte 4
Byte 5
Field length
identifier
0003 hex
FF hex
p.167
Host Communications Specifications
Description
Byte 6
Byte 7
Byte 8
Unit
Function
Exception
code
code
83 hex
1 byte
Description