Omron V680 Series User Manual page 204

Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

Section 7
Host Communications Specifications
 GET SYSTEM ERROR LOG
This query reads the log of system errors (fatal errors) that have occurred in the Reader/Writer.
 Query Format
Byte 0
Byte 1
Transaction
identifier
X
Parameter
Register address
Word count
 Response Format
Normal Response
Byte 0
Byte 1
Byte 2
Transaction identifier
Protocol identifier
X
X
0000 hex
Byte count
Number of record
System error log
record information
Error Response
Byte 0
Byte 1
Transaction
identifier
X
Parameter
Exception code
 Execution Example
Reading the System Error Log When an Error with an Error Code of 10010000 Occurred at an
Operating Time of 1111111111 and an Error with an Error Code of 20030000 Occurred at an
Operating Time of 2222222222 (No Attached Information for Either Error)
TX: 000000000006FF03C5000041
RX: 000000000085FF03820002423A35C710010000000000000000000084746B8E20030000000000000000000000000000···00
RFID System
202
User's Manual
(Modbus TCP)
Byte 2
Byte 3
Byte 4
Protocol identifier
Field length
X
0000 hex
0006 hex
The register address (C500 hex) that specifies the system error log information.
The number of words in the system error log information to read (0041 hex)
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Unit
Field length
identifie
Function code
r
0085 hex
FF hex
03 hex
Byte 11
···
Byte 14
Operating time
4 bytes
Parameter
Operating time
Error code
Attached information 1
Attached information 2
Byte 2
Byte 3
Byte 4
Protocol identifier
X
0000 hex
For details, refer to Exception Code Table in this section.
p.167
Byte 5
Byte 6
Byte 7
Unit
Function
identifier
code
FF hex
03 hex
Description
Byte 8
Byte 9
Byte 10
Byte count
Number of records
82 hex
1 word
Byte 15
···
Byte 18
Byte 19
···
Error code
Attached information 1
4 bytes
4 bytes
The number of bytes in the system error log that was read (82 hex)
The number of record in the system error log that was read.
The operating time from when the Reader/Writer was started in 8-digits
hexadecimal (Unit: ms)
For details, refer to Error Codes in this section.
p.168
Byte 5
Byte 6
Byte 7
Unit
Function
Field length
identifier
0003 hex
FF hex
83 hex
Description
Byte 8
Byte 9
Byte 10 Byte 11
Register address
C500 hex
Byte 11
···
Byte 26
···
Byte 123
Most recent system error record
Most recent system error log
···
information
record information 7
8 words
···
Byte 22
Byte 23
···
Byte 26
Attached information 2
4 bytes
Description
Byte 8
Exception
code
code
1 byte
Word count
0041 hex
···
Byte 138
8 words