Omron V680 Series User Manual page 214

Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

Section 7
Host Communications Specifications
 SET MULTI-READER/WRITER SETTINGS
This query sets the Multi-Reader/Writer settings.
 Query Format
Byte-0
Byte-1
Transaction
identifier
X
X
Register address
Word count
Byte count
Multi-Reader/
Writer settings
 Response Format
Normal Response
Byte-0
Byte-1
Transaction
identifier
X
X
Register address
Word count
Error Response
Byte-0
Byte-1
Transaction
identifier
X
X
Parameter
Exception code
RFID System
212
User's Manual
(Modbus TCP)
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Protocol
Unit
Field length
identifier
identifier
0000 hex
0027 hex
FF hex
Byte-13
Byte-14
Multi-Reader/
Writer Mode
2 bytes
Parameter
This is the register address that is specified in the Multi-Reader/Writer settings (B400
hex).
This is the number of words in the Multi-Reader/Writer settings (0010 hex).
This is the number of bytes in the Multi-Reader/Writer settings (20 hex).
Multi-Reader/
Specify in 4-digit hexadecimal whether to enable or disable Multi-Reader/Writer settings.
Writer Mode
0000 hex: Disable (default setting)
0001 hex: Enable for Field Extension Mode
0002 hex: Enable for High-speed Traveling Mode
Number of Slave
Specify in 4-digit hexadecimal the number of Slave Reader/Writers to link with Reader/
Reader/Writers
Writer extension.
Setting range: 0000 to 0007 hex
IP address 1
Specify in 8-digit hexadecimal the IP addresses to set.
Setting range: 0000 0000 to FFFF FFFF hex
:
Example: C0A801C8 hex (192.168.1.200)
IP address 7
Byte-2 Byte-3 Byte-4 Byte-5
Byte-6
Protocol
Unit
Field length
identifier
identifier
0000 hex
0006 hex
FF hex
Parameter
The register address from the query is set.
The word count from the query is set.
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code Table in this section.
p.167
Byte-7
Byte-8
Byte-9
Byte-10
Register
Function code
Word count
address
10 hex
B400 hex
0010 hex
Byte-15
Byte-16
Byte-17
Byte-18
Byte-19
Number of Slave
IP address 1
Reader/Writers
2 bytes
4 bytes
Description
Byte-7
Byte-8
Byte-9
Byte-10
Function code
Register address
10 hex
B400 hex
Description
Byte-6
Byte-7
Byte-8
Unit
Exception
Function code
identifier
code
FF hex
90 hex
1 byte
Description
Byte-11
Byte-12
Byte-13
...
Multi-Reader/Writer
Byte count
settings
20 hex
32 bytes
Byte-20
...
Byte-41
Byte-42
Byte-43
IP address 7
4 bytes
Byte-11
Word count
0010 hex
Byte-44
Byte-44