Omron V680 Series User Manual page 316

Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

Section 11
Appendices
 Mutual Interference of RF Tags
If you use more than one RF Tag, separate them by at least the interval shown below to prevent
malfunctions due to mutual interference.
If the distance between the RF tags is too short, read / write distance will be reduced.
 V680S-HMD64-ETN Reader/Writer
 V680S-HMD66-ETN Reader/Writer
 Influence of Inclination
Install the Reader/Writer and RF Tags so that the Reader/Writer and RF Tags are as parallel to each
other as possible.
Communications will be possible even if the Reader/Writer and RF Tags are not parallel to each other;
however, the communications range is affected by the inclination between them as shown in the
following graphs.
 Rates of Change in Communications Range for Inclination of V680S-D2KF68M
V680S-HMD64-ETN and V680S-D2KF68M
horizontally
V680S-HMD64-ETN and V680S-D2KF68M
vertically
V680S-HMD66-ETN and V680S-D2KF68M
horizontally
V680S-HMD66-ETN and V680S-D2KF68M
vertically
RFID System
314
User's Manual
(Modbus TCP)
100 mm min.
100 mm min.
130 mm min.
120 mm min.
0
10
0%
0%
0%
-2%
0%
-1%
0%
-1%
100 mm min.
100 mm min.
130 mm min.
120 mm min.
(θ°)
RF Tag inclination
20
30
40
50
60
-1%
-3%
-5%
-9%
-17%
-4%
-7%
-12%
-19%
-31%
-2%
-4%
-8%
-13%
-23%
-4%
-7%
-12%
-21%
-33%
70
80
90
-32%
---
---
-51%
---
---
-43%
---
---
-58%
---
---

Advertisement