Omron V680 Series User Manual page 216

Modbus tcp reader/writer
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

Section 7
Host Communications Specifications
 GET MULTI-READER/WRITER SETTINGS
This query reads the Multi-Reader/Writer settings.
Query Format
Byte-0
Byte-1
Transaction
identifier
X
X
Register address
Word count
 Response Format
Normal Response
Byte-0
Byte-1
Transaction
identifier
X
X
Byte count
Multi-Reader/
Writer settings
Error Response
Byte-0
Byte-1
Transaction
identifier
X
X
Parameter
Exception code
When the Extension Settings are set to Link Two Slave Reader/Writers (IP Address 1: 192.168.1.201,
IP Address 2: 192.168.1.202) and to Enable Multi-Reader/Writer Settings in Field Extension Mode
TX:000000000006FF03B4000010
RX:000000000024FF032000010002C0A801C9C0A801CA0000000000000000000000000000000000000000
RFID System
214
User's Manual
(Modbus TCP)
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0006 hex
Parameter
This is the register address that is specified in the Multi-Reader/Writer settings (B400
hex).
This is the number of words in the Multi-Reader/Writer settings (0010 hex).
Byte-2
Byte-3
Byte-4
Byte-5
Byte-6
Protocol
Unit
Field length
identifier
identifier
0000 hex
0024 hex
FF hex
Byte-9
Byte-10
Multi-Reader/Writer
Mode
2 bytes
Parameter
This is the number of bytes in the Multi-Reader/Writer settings (20 hex).
Multi-Reader/
Indicates whether to enable or disable Multi-Reader/Writer settings in 4-digit
Writer Mode
hexadecimal.
0000 hex: Disable (default setting)
0001 hex: Enable for Field Extension Mode
0002 hex: Enable for High-speed Traveling Mode
Number of Slave
Contains the number of Slave Reader/Writers to link with Reader/Writer extension in 4-
Reader/Writers
digit hexadecimal.
0000 to 0007 hex
IP address 1
Contain the IP addresses that are set 4-digit hexadecimal.
0000 0000 to FFFF FFFF hex
:
Example: C0A80101 hex (192.168.1.1)
IP address 7
Byte-2
Byte-3
Byte-4
Byte-5
Protocol identifier
Field length
0000 hex
0003 hex
For details, refer to Exception Code Table in this section.
p.167
Byte-6
Byte-7
Byte-8
Byte-9
Unit
Function code
Register number
identifier
FF hex
03 hex
B400 hex
Description
Byte-7
Byte-8
Byte-9
Multi-Reader/Writer
Function code
Byte count
03 hex
20 hex
Byte-11
Byte-12
Byte-13
Byte-14
Byte-15
Number of Slave
IP address 1
Reader/Writers
2 bytes
4 bytes
Description
Byte-6
Byte-7
Byte-8
Unit
Exception
Function code
identifier
code
FF hex
83 hex
1 byte
Description
Byte-10
Byte-11
Word count
0010 hex
...
Byte-40
status
32 bytes
Byte-16
...
Byte-37
Byte-38
Byte-39
IP address 7
4 bytes
Byte-40