TTYCSLA-1
Shield
Armor
Sheath
3
10
Wind drain wire around vinyl sheath.
Wrap drain wire with tape conductor for
grounding.
Fix with vinyl tape for protection against
injury.
Insert the wire to connector case and
solder the wire to the pin.
Clamp tape conductor with a connector clamp for grounding.
DPYCY
Armor
Sheath
Outer Sheath
3
Scrape the paint for grounding.
Insert the wire to connector case and
solder the wire to the pin.
Clamp the sheath with connector clamp of connector case.
Fabricating of connectors for external equipment
ES: SRCN6A16-7P
GYRO: SRCN6A13-5P
NMEA1/CIF1, NMEA2/CIF2,: SRCN6A16-10P
LOG: SRCN6A13-3P
3
Core
Drain wire
20
3
Core
25
20
Connector clamp
Connector case
Connector clamp
Connector case