Furuno CSH8LMK2 Installation Manual page 33

Color scanning sonar
Table of Contents

Advertisement

2.3.3
Changing the power specification
Change jumper wires on the transceiver unit according to ship's mains. Follow the la-
bel on the power block in the transceiver unit. Attach the other end of the wire plugged
in #3 (COM) into one of #4 (100 V) thru #8 (240 V) depending on ship's mains. Also,
change the power fuse appropriately. On the stickers at the terminal board and back
of the front lid of the transceiver unit, change the mark position for the used fuse.
100 VAC series (100/110/115 VAC)
220 VAC series (200/220/240 VAC)
2.3.4
How to unplug the XH connector
If making a wrong connection of XH connector, use XH connector remover to unplug
the XH connector.
Ship's mains
Jumper wire
Transceiver unit power block
XH connector remover
Fuse
7 A 125 V
4 A 250 V
Power fuse
Power block
(Lower left side of
transceiver unit)
Pull board slightly.
XH connector
Connector remover
2. WIRING
2-7