2. WIRING
2.3.1
Transducer cable wiring
Separate the cable in two, pass it through cable clamp [A] and fix it with a cable tie.
Pass the cable through cable clamp [B] and fix with cable tie. Pass cable through cable
clamp at the side of the transceiver unit.
Fix by cable clamp.
(See Note 1.)
Note 1: Wire unit with cable clamps in horizontal position. Lay cable clamp after fin-
ishing wiring.
1) Lay braided shields of
transducer cable in cable
clamp. Each cable is num-
bered; connect referring to
the illustration on the pre-
ceding page.
2) Unfasten two bolts.
3) Set the clamp and fasten it
with two bolts removed at
step 2.
Note 1: When fixing transduc-
er cable with cable clamp, wrap with vinyl tape before fixing, or wrap the cable with a
piece of the outer sheath of the cable and fix by cable clamp.
2.3.2
Power cable
Vinyl sheath
Note: When connecting the power cable, the crimp on lug of the capacitor is removed.
Do not forget to reattach the crimp on lug of the capacitor to the terminal board.
2-6
Cable clamp [A]
Transceiver unit, upper view
Clamp base
40
5
Armor
Fabrication of power cable
Cable clamp [B]
Fix by two cable ties.
Transducer cable
Cable clamp
(See Note 2.)
(Can be placed
on left side.)
Clamp
Bolts
FV5.5-4 TB-B1
100