Ricoh Aficio SP C440DN Field Service Manual page 419

Hide thumbs Also See for Aficio SP C440DN:
Table of Contents

Advertisement

3531
[No-use ProCon Set]
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at stand-
by is executed.
3-531-001 No-Use Time Set
3-531-002 Temperature Range
3-531-003 RHumidity Change
3-531-004 AHumidity Change
3-531-005 Max. Exe. Number
3611
[DevGamma:Dspl/Set]
3-611-001 Bk (Current)
3-611-002 C (Current)
3-611-003 M (Current)
3-611-004 Y (Current)
3-611-005 Bk(TargetDisplay)
3-611-006 C (TargetDisplay)
3-611-007 M (TargetDisplay)
3-611-008 Y (TargetDisplay)
3800
[Toner Collection Bttl Full]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1 deg/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m
*ENG
Adjusts the maximum execution time for the
process control at stand-by.
[0 to 99 / 10 / 1 time/step]
*ENG
Displays the current development gamma for
Bk
[0 to 5 / 0 / 0.01 mg/cm
*ENG
Displays the current development gamma for
C/M/Y.
*ENG
[0 to 5 / 0 / 0.01 mg/cm
*ENG
*ENG
Displays the target development gamma for Bk.
[0 to 5 / 0.85 / 0.01 mg/cm
*ENG
Displays the target development gamma for
C/M/Y.
[0 to 5 / 0.85 / 0.01 mg/cm
*ENG
[0 to 5 / 0.8 / 0.01 mg/cm
*ENG
[0 to 5 / 0.77 / 0.01 mg/cm
Engine SP Mode Tables - SP3000
3
/step]
2
/kV /step]
2
/kV /step]
2
/kV /step]
2
/kV /step]
2
/kV /step]
2
/kV /step]
417