Ricoh Aficio SP C440DN Field Service Manual page 278

Hide thumbs Also See for Aficio SP C440DN:
Table of Contents

Advertisement

5. System Maintenance Reference
1105
1-105-001 Fusing Ready Temp
1-105-002 Fusing Ready: Offset
1-105-003 PR:RdyTrgt Temp.
1-105-007 P-Roll Ready Temp
1-105-010 Stand-By: Center
1-105-011 Stand-By: Ends
1-105-012 Stand-By:P-Roller
1-105-013 Panel Off: Center
1-105-014 Panel Off: Ends
276
[Fusing Temp.] Fusing Temperature Adjustment
(Printing Mode, Roller Type, [Color], Simplex/Duplex)
Roller Type –> Center and Ends: Heating roller, P-Roller or PR –> Pressure roller
Paper Type -> Plain, Thin, Thick, OHP, Middle Thick, Special
Printing Mode -> S: Simplex, D: Duplex
Specifies the heating roller target temperature for the ready condition.
Specifies the pressure roller target temperature for the ready condition.
Specifies the subtracted temperature of the pressure roller for the fusing reload start.
Specifies the target temperature of the pressure roller for the stand-by mode.
Specifies the heating roller temperature (center) in the panel off mode.
Specifies the heating roller temperature (both ends) in the panel off mode.
*ENG
[100 to 180 / 160 / 1 deg/step]
*ENG
[5 to 30 / 11 / 1 deg/step]
Specifies the subtracted temperature
of the heating roller for the fusing
reload start.
*ENG
[50 to 160 / 120 / 1 deg/step]
*ENG
[0 to 150 / 20 / 1 deg/step]
* ENG
[50 to 180 / 160 / 1 deg/step]
Specifies the target center
temperature of the heating roller
(center) for the stand-by mode.
* ENG
[50 to 180 / 160 / 1 deg/step]
Specifies the target temperature of
the heating roller (ends) for the
stand-by mode.
* ENG
[50 to 160 / 140 / 1 deg/step]
* ENG
[50 to 180 / 140 / 1 deg /step]
* ENG
[50 to 180 / 140 / 1 deg /step]