5. System Maintenance Reference
1-113-003 WaitTime AF Rcvry
Specifies the time for keeping the target temperature without any jobs after recovery
(SP1105-083).
1-113-004 Wait Time AF Job
Specifies the time for keeping the target temperature without any jobs after a last job.
1-113-005 PR Thresh AF Rdy
Specifies the threshold temperature of the pressure roller for entering the wait time
mode (SP1-113-001).
1-113-006 PR Thresh AF Job
Specifies the threshold temperature of the pressure roller for entering the wait time
mode (SP1-113-004).
1-113-008 On/Off SW Timer
Specifies the interval for entering the PID control from the On/Off control.
1115
[Stand-by Idling]
1-115-001 Interval
Specifies the interval between idling during stand-by mode.
This idling during the stand-by mode prevents the roller deformation.
1-115-002 Idling Time
Specifies the length of each idling operation during stand-by mode.
1-115-003 Idling Speed
1116
[Fusing Temp Change]
Paper Type –> MThick: Middle Thick
286
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 60 / 10 / 1 sec/step]
*ENG
[0 to 160 / 120 / 1 deg/step]
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
[0 to 999 / 300 / 1 sec/step]
*ENG
[0 to 240 / 60 / 1 min/step]
*ENG
[0 to 60 / 2 / 0.1 sec/step]
*ENG
[0 or 1 / 0 / 1 /step]
0: Half SPD, 1: Full SPD
Selects the line speed for the stand-by
idling.