Other Can Bus Commands; Site Controller Configuration And Verification - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Other CAN Bus Commands

Other CAN Bus Commands
Other CAN Bus Commands for mapping Track IDs are described in the appropriate
chapters as a part of a replacement procedure.:
can check_mapping lists the registered, unregistered and unknown devices connected through CAN Bus.
Example:
SC> can check_mapping
Units are present:
Device Track ID
DPM 1 JTH0500101
PSU 1 JTH0500200
Units are not present:
DPM 2 JTH0500105
Track ID not mapped
JTH0500102
Site Controller Configuration and Verification
The Site controller (SC) setup and checkout procedures specify steps that verify operation within
the Site Controller. The Site Controller verification consists of:
Process 6-2 The Site controller (SC) setup and checkout procedures.
1
2
3
6-10
If there are no devices present, this means the cabling is possibly corrupted.
All
devices should be mapped.
not mapped
"Site Controller Setup"
- Describes how to verify the Site Controller Configuration
"E1 Connection Test" "X.21 Connection Test"
to test E1 (X.21) interface and cabling
"Site Reference Check"
- Describes how to check for proper SRI functioning.
- Describes how to perform E1 (X.21) Loopback
Chapter 6: Configuration and Testing
6802800U74-N September 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4

Table of Contents