MTS 4 CAN Bus Cabling
MTS 4 CAN Bus Cabling
The Site Controller contains the internal termination in one end of the CAN Bus, and the last
Duplexer in the CAN Bus has a terminator in one connector.
and
Figure 5-27
Table 5-28 CAN Bus Cabling for MTS 4 with TX/RX or TX on 1 ant.
Cable Part
Index
MTS 4 (TX/RX or TX on 1 ant. with ATCCs)
1
3066575B01
2
3066544B06
3
3066544B09
4
3066544B09
5
3066544B06
6
3066575B01
7
0966513A01 Power Supply Unit 2/ CAN2
5-54
and
Figure 5-28
show the CAN Bus cabling in MTS 4.
CAN Bus cabling depends on filter configuration.
From Unit / Connection
Number
Site Controller 1/ CAN
Power Supply Unit 1/ CAN2
Duplexer or Post Filter/ CAN2 ATCC 1/ CAN1
ATCC 1/ CAN2
ATCC 2/ CAN2
Power Supply Unit 2/ CAN2
When MTCCs or HCs are used instead of ATCCs, the CAN Bus is connected directly from
Duplexer or Post Filter/ CAN2 connector to Power Supply Unit 2/ CAN1 connector.
Table 5-28
To Unit / Connection Name
Name
Power Supply Unit 1/ CAN1
Duplexer or Post Filter/ CAN1
ATCC 2/ CAN1
Power Supply Unit 2/ CAN1
Site Controller 2/ CAN
CAN Bus termination
Chapter 5: Interconnection and Internal Cabling
and
Table 5-29
identify
Red cable
Red cable
Red cable
Red cable
Red cable
With
redundant Site
Controller/
red cable
Without
redundant Site
Controller